Review




Structured Review

TA Instruments nano itc calorimeter
Nano Itc Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pmc10083169__41467_2023_37757_MOESM1_ESM-25-5-8
Average 90 stars, based on 1 article reviews
nano itc calorimeter - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Recombinant:

Article Title: Ginsenoside Rk2 alleviates hepatic ischemia/reperfusion injury by enhancing AKT membrane translocation and activation
Article Snippet: .. Calorimetric measurements of the interaction between Rk2 and human recombinant AKT1 were conducted using a Nano ITC calorimeter (TA Instruments). ..

Isothermal Titration Calorimetry:

Article Title: Selective cargo and membrane recognition by SNX17 regulates its interaction with Retriever
Article Snippet: .. Isothermal titration calorimetry (ITC) experiments were carried out on a Nano ITC calorimeter (TA Instruments). ..

Article Title: The E3 ligase HUWE1 interacts with ubiquitin non-covalently via key residues in the HECT domain.
Article Snippet: 1 Department of Pathogen Biology, School of Basic Medicine, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 2 Department of Infectious Disease, Tongji Hospital, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 3 Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China 4 Hubei Key Laboratory of Drug Target Research and Pharmacodynamic Evaluation, Wuhan, China 5 Tongji-Rongcheng Center for Biomedicine, Huazhong University of Science and Technology, Wuhan, China

Article Title: Selective cargo and membrane recognition by SNX17 regulates its interaction with Retriever.
Article Snippet: The Retriever complex recycles a wide range of transmembrane proteins from endosomes to the plasma membrane.. The cargo adapter protein SNX17 has been implicated in recruiting the Retriever complex to endosomal membranes, yet the details of this interaction have remained elusive.. Through biophysical and structural model-guided mutagenesis studies with recombinant proteins and liposomes, we have gained a deeper understanding of this process.

Software:

Article Title: A cationic motif upstream Engrailed2 homeodomain controls cell internalization through selective interaction with heparan sulfates
Article Snippet: .. Experiments were acquired with a Nano ITC calorimeter (TA Instruments, New Castle, DE, USA) and analyzed with the Nanoanalyze software provided by the supplier. ..

Nuclear Magnetic Resonance:

Article Title: Enzyme-Mediated Dynamic Combinatorial Chemistry Enables Large-Scale Synthesis of δ-Cyclodextrin
Article Snippet: .. Data from NMR spectroscopy titrations was analyzed using the supramolecular.org web applet (https://supramolecular.org).3,4 ITC titration experiments were performed on a TA Instruments Nano ITC calorimeter equipped with a “standard volume” (SV) cell of 998 μl. ..

Spectroscopy:

Article Title: Enzyme-Mediated Dynamic Combinatorial Chemistry Enables Large-Scale Synthesis of δ-Cyclodextrin
Article Snippet: .. Data from NMR spectroscopy titrations was analyzed using the supramolecular.org web applet (https://supramolecular.org).3,4 ITC titration experiments were performed on a TA Instruments Nano ITC calorimeter equipped with a “standard volume” (SV) cell of 998 μl. ..

Titration:

Article Title: Enzyme-Mediated Dynamic Combinatorial Chemistry Enables Large-Scale Synthesis of δ-Cyclodextrin
Article Snippet: .. Data from NMR spectroscopy titrations was analyzed using the supramolecular.org web applet (https://supramolecular.org).3,4 ITC titration experiments were performed on a TA Instruments Nano ITC calorimeter equipped with a “standard volume” (SV) cell of 998 μl. ..

Binding Assay:

Article Title: The E3 ligase HUWE1 interacts with ubiquitin non-covalently via key residues in the HECT domain.
Article Snippet: 1 Department of Pathogen Biology, School of Basic Medicine, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 2 Department of Infectious Disease, Tongji Hospital, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 3 Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China 4 Hubei Key Laboratory of Drug Target Research and Pharmacodynamic Evaluation, Wuhan, China 5 Tongji-Rongcheng Center for Biomedicine, Huazhong University of Science and Technology, Wuhan, China

Mutagenesis:

Article Title: The E3 ligase HUWE1 interacts with ubiquitin non-covalently via key residues in the HECT domain.
Article Snippet: 1 Department of Pathogen Biology, School of Basic Medicine, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 2 Department of Infectious Disease, Tongji Hospital, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, China 3 Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China 4 Hubei Key Laboratory of Drug Target Research and Pharmacodynamic Evaluation, Wuhan, China 5 Tongji-Rongcheng Center for Biomedicine, Huazhong University of Science and Technology, Wuhan, China



Similar Products

86
Malvern Panalytical nano itc lv isothermal titration calorimeter
Nano Itc Lv Isothermal Titration Calorimeter, supplied by Malvern Panalytical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/bio_rxiv__64898__2026__03__24__713787-200-7-12
Average 86 stars, based on 1 article reviews
nano itc lv isothermal titration calorimeter - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
TA Instruments nano itc calorimeter
Nano Itc Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pmc10083169__41467_2023_37757_MOESM1_ESM-25-5-8
Average 90 stars, based on 1 article reviews
nano itc calorimeter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments nano isothermal titration calorimetry (itc)-lv calorimeter
Nano Isothermal Titration Calorimetry (Itc) Lv Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pm40639525-125-15-21
Average 90 stars, based on 1 article reviews
nano isothermal titration calorimetry (itc)-lv calorimeter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments calorimeter instrument nano itc
Calorimeter Instrument Nano Itc, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pm40562125-102-5-9
Average 90 stars, based on 1 article reviews
calorimeter instrument nano itc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments isothermal titration calorimeter nano itc
Isothermal Titration Calorimeter Nano Itc, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pm40490352-73-6-11
Average 90 stars, based on 1 article reviews
isothermal titration calorimeter nano itc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments isothermal calorimeter nano itc
Isothermal Calorimeter Nano Itc, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/10__1016_slash_j__jcis__2025__138235-46-9-13
Average 90 stars, based on 1 article reviews
isothermal calorimeter nano itc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments nano itc isothermal titration calorimeter
Nano Itc Isothermal Titration Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pm39979266-101-49-52
Average 90 stars, based on 1 article reviews
nano itc isothermal titration calorimeter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments itc nano active control calorimeter
Thermodynamic study: <t>ITC</t> and all-atom MD simulations. (a) Representative thermogram depicting the corrected heat rate measured when adding 1.5 mM total lipid concentration of POPC/GM 1 (96/4) to 2 μM of Gal-1 as a function of time. Controlled and precise additions of POPC/GM 1 LUVs were performed to a solution of Gal-1 (10 mM PBS, 137 mM NaCl, and 0.27 mM KCl, pH = 7.4). Keeping the same instrumental setup, analogous additions to PBS (without Gal-1) of POPC/GM 1 LUVs were made. These control experiments were necessary to obtain the blank titrations, which were subtracted from the sample measurements in the context of analyzing the reaction heats. (b) Thermodynamic parameters (Δ G , Δ H , Δ S ) and their associated error bars indicating the standard deviation obtained titrating POPC/GM 1 (96/4) to a Gal-1 solution. The thermodynamic data were gained from a global analysis performed by using HypCal software ( n = 3). (c) PMF of Gal-1 dimer dissociation in water obtained using the umbrella sampling technique. The PMF was calculated using the weighted histogram analysis method implemented in GROMACS. Standard error bands (light green) are calculated using the Bayesian bootstrapping method. (d) Probability of the Gal-1 dimer binding to five different bilayers, i.e., POPC, POPC/GM 1 (96/4), POPC/GM 1 (90/10), POPC/GD 1 a (96/4), and POPC/GD 1 a (90/10), represented by the different bars. The bars’ dark and pale gray portions represent the contacts to POPC and GM 1 or GD 1 a in each different bilayer composition, respectively (see </xref> for details).
Itc Nano Active Control Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pmc12183518-104-7-12
Average 90 stars, based on 1 article reviews
itc nano active control calorimeter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TA Instruments low volume nano itc calorimeter
Thermodynamic study: <t>ITC</t> and all-atom MD simulations. (a) Representative thermogram depicting the corrected heat rate measured when adding 1.5 mM total lipid concentration of POPC/GM 1 (96/4) to 2 μM of Gal-1 as a function of time. Controlled and precise additions of POPC/GM 1 LUVs were performed to a solution of Gal-1 (10 mM PBS, 137 mM NaCl, and 0.27 mM KCl, pH = 7.4). Keeping the same instrumental setup, analogous additions to PBS (without Gal-1) of POPC/GM 1 LUVs were made. These control experiments were necessary to obtain the blank titrations, which were subtracted from the sample measurements in the context of analyzing the reaction heats. (b) Thermodynamic parameters (Δ G , Δ H , Δ S ) and their associated error bars indicating the standard deviation obtained titrating POPC/GM 1 (96/4) to a Gal-1 solution. The thermodynamic data were gained from a global analysis performed by using HypCal software ( n = 3). (c) PMF of Gal-1 dimer dissociation in water obtained using the umbrella sampling technique. The PMF was calculated using the weighted histogram analysis method implemented in GROMACS. Standard error bands (light green) are calculated using the Bayesian bootstrapping method. (d) Probability of the Gal-1 dimer binding to five different bilayers, i.e., POPC, POPC/GM 1 (96/4), POPC/GM 1 (90/10), POPC/GD 1 a (96/4), and POPC/GD 1 a (90/10), represented by the different bars. The bars’ dark and pale gray portions represent the contacts to POPC and GM 1 or GD 1 a in each different bilayer composition, respectively (see </xref> for details).
Low Volume Nano Itc Calorimeter, supplied by TA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nano+itc+calorimeter/nano+itc+calorimeter/pm40324743-249-7-10
Average 90 stars, based on 1 article reviews
low volume nano itc calorimeter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Thermodynamic study: ITC and all-atom MD simulations. (a) Representative thermogram depicting the corrected heat rate measured when adding 1.5 mM total lipid concentration of POPC/GM 1 (96/4) to 2 μM of Gal-1 as a function of time. Controlled and precise additions of POPC/GM 1 LUVs were performed to a solution of Gal-1 (10 mM PBS, 137 mM NaCl, and 0.27 mM KCl, pH = 7.4). Keeping the same instrumental setup, analogous additions to PBS (without Gal-1) of POPC/GM 1 LUVs were made. These control experiments were necessary to obtain the blank titrations, which were subtracted from the sample measurements in the context of analyzing the reaction heats. (b) Thermodynamic parameters (Δ G , Δ H , Δ S ) and their associated error bars indicating the standard deviation obtained titrating POPC/GM 1 (96/4) to a Gal-1 solution. The thermodynamic data were gained from a global analysis performed by using HypCal software ( n = 3). (c) PMF of Gal-1 dimer dissociation in water obtained using the umbrella sampling technique. The PMF was calculated using the weighted histogram analysis method implemented in GROMACS. Standard error bands (light green) are calculated using the Bayesian bootstrapping method. (d) Probability of the Gal-1 dimer binding to five different bilayers, i.e., POPC, POPC/GM 1 (96/4), POPC/GM 1 (90/10), POPC/GD 1 a (96/4), and POPC/GD 1 a (90/10), represented by the different bars. The bars’ dark and pale gray portions represent the contacts to POPC and GM 1 or GD 1 a in each different bilayer composition, respectively (see </xref> for details).

Journal: ACS Bio & Med Chem Au

Article Title: Unraveling the GM 1 Specificity of Galectin‑1 Binding to Lipid Membranes

doi: 10.1021/acsbiomedchemau.5c00040

Figure Lengend Snippet: Thermodynamic study: ITC and all-atom MD simulations. (a) Representative thermogram depicting the corrected heat rate measured when adding 1.5 mM total lipid concentration of POPC/GM 1 (96/4) to 2 μM of Gal-1 as a function of time. Controlled and precise additions of POPC/GM 1 LUVs were performed to a solution of Gal-1 (10 mM PBS, 137 mM NaCl, and 0.27 mM KCl, pH = 7.4). Keeping the same instrumental setup, analogous additions to PBS (without Gal-1) of POPC/GM 1 LUVs were made. These control experiments were necessary to obtain the blank titrations, which were subtracted from the sample measurements in the context of analyzing the reaction heats. (b) Thermodynamic parameters (Δ G , Δ H , Δ S ) and their associated error bars indicating the standard deviation obtained titrating POPC/GM 1 (96/4) to a Gal-1 solution. The thermodynamic data were gained from a global analysis performed by using HypCal software ( n = 3). (c) PMF of Gal-1 dimer dissociation in water obtained using the umbrella sampling technique. The PMF was calculated using the weighted histogram analysis method implemented in GROMACS. Standard error bands (light green) are calculated using the Bayesian bootstrapping method. (d) Probability of the Gal-1 dimer binding to five different bilayers, i.e., POPC, POPC/GM 1 (96/4), POPC/GM 1 (90/10), POPC/GD 1 a (96/4), and POPC/GD 1 a (90/10), represented by the different bars. The bars’ dark and pale gray portions represent the contacts to POPC and GM 1 or GD 1 a in each different bilayer composition, respectively (see for details).

Article Snippet: The experiments were performed by using an ITC Nano Active Control Calorimeter (TA Instruments, New Castle, DE, USA) and Auto-iTC200 (Malvern Panalytical, Malvern, United Kingdom).

Techniques: Concentration Assay, Control, Standard Deviation, Software, Sampling, Binding Assay